Institut Kejuruteraan Nano Elektronik

Universiti Malaysia Perlis

  • Facebook
  • Instagram
  • Twitter
  • YouTube
  • Tentang Kami
    • Latar Belakang
    • Misi dan Visi
    • Organisasi
    • Piagam Pelanggan
    • Video Korporat
    • Kepakaran Kami
    • Pengakuan
    • Brosur
  • Ahli akademik
    • Sarjana Sains
    • Doktor Falsafah
    • Pelajar Pascasiswazah
    • Alumni
  • Penyelidikan
    • Aktiviti Penyelidikan
      • Bidang Penyelidikan
      • Fokus Penyelidikan
      • Projek Penyelidikan
        • Produk
      • Kerjasama
      • Penerbitan
        • Papan skor
    • Kemudahan Penyelidikan
  • Hubungi Kami
    • Direktori Kakitangan
    • Maklum balas
  • Galeri
    • Video
    • Audio
  • Muat turun
    • Arkib
    • Penerbitan
    • Borang
    • Kesedaran OBE
    • Laporan
  • Pautan Pantas
    • Pautan Sokongan
    • Soalan Lazim
    • Peta Laman
    • Fakulti
    • Jabatan Lain
    • Acara

Archives for June 2016

Electrical detection of dengue virus (DENV) DNA oligomer using silicon nanowire biosensor with novel molecular gate control

June 21, 2016 Oleh Editor

Abstract – In this paper, a silicon nanowire biosensor with novel molecular gate control has been demonstrated for Deoxyribonucleic acid (DNA) detection related to dengue virus (DENV). The silicon nanowire was fabricated using the top-down nanolithography approach, through nanostructuring of silicon-on-insulator (SOI) layers achieved by combination of the electron-beam lithography (EBL), plasma dry etching and size reduction processes. The surface of the fabricated silicon nanowire was functionalized by means of a three-step procedure involving surface modification, DNA immobilization and hybridization. This procedure acts as a molecular gate control to establish the electrical detection for 27-mers base targets DENV DNA oligomer. The electrical detection is based on the changes in current, resistance and conductance of the sensor due to accumulation of negative charges added by the immobilized probe DNA and hybridized target DNA. The sensitivity of the silicon nanowire biosensors attained was 45.0 μA M-1, which shows a wide-range detection capability of the sensor with respect to DNA. The limit of detection (LOD) achieved was approximately 2.0 fM. The demonstrated results show that the silicon nanowire has excellent properties for detection of DENV with outstanding repeatability and reproducibility performances.

Keywords – Dengue fever (DF); Deoxyribonucleic acid (DNA); Electrical detection; Molecular gate control; Nanolithography; Silicon nanowire biosensor

Corresponding Author: Mohammad Nuzaihan Md Nor
Corresponding Author’s Email: m.nuzaihan@unimap.edu.my

Teks penuh: PDF

Filed Under: Publications Tagged With: Dengue fever, Deoxyribonucleic acid, DF, dna, Electrical detection, Molecular gate control, Nanolithography, Silicon nanowire biosensor

BERITA @ INEE

  • IJNeaM Achieves a JCR Impact Factor of 0.8
  • Taklimat Hala Tuju Penyelidikan oleh Timbalan Naib Canselor Penyelidikan & Inovasi (TNC P&I) dan Pencapaian INEE 2022-2025
  • Sentuhan Kasih INEE 2026M/1447H
  • Program Cahaya Prihatin: Elektrik Untuk Masyarakat 2025
  • Persidangan Antarabangsa ke-2 mengenai Nanoteknologi & Penyelidikan Bahan (ICONMAR 2025)

ACARA & AKTIVITI

  • Lawatan daripada Fakulti Teknologi Lanjutan dan Pelbagai Disiplin (FTMM), Universitas Airlangga
  • Lawatan daripada Syarikat Aromaticroot
  • Panggilan untuk Kertas Kerja: BOND21 2026
  • Lawatan oleh Pelajar SJK (C) Nan Kwang
  • Jelajah INEE Nano – Siri 4
Dasar Privasi | Dasar Keselamatan | Penafian | Peta Laman | Soalan Lazim | Maklum balas | Panduan Pengguna | Muat turun | Siswazah

Institut Kejuruteraan Nano Elektronik, Universiti Malaysia Perlis
Lot 106, 108 & 110, Blok A, Taman Pertiwi Indah,
Jalan Kangar-Alor Setar, Seriab 01000 Kangar, Perlis, Malaysia
Tel: +604-979 8581 Faks: +604-979 8578 Emel: webmaster.inee@unimap.edu.my

Hak Cipta © INEE UniMAP

  • Facebook
  • Instagram
  • Twitter
  • YouTube

Untuk paparan terbaik, sila gunakan versi terkini Internet Explorer, Mozilla Firefox dan Google Chrome dengan resolusi 1280 x 768 dan ke atas.

Rakan Kongsi BioNexus (BNP)

QS 5 Bintang

myGov

Logo UniMAP

Designed by Mohd Isa from Portal Kerjaya & Sumber Rujukan Malaysia

  • English