Institut Kejuruteraan Nano Elektronik

Universiti Malaysia Perlis

  • Facebook
  • Instagram
  • Twitter
  • YouTube
  • Tentang Kami
    • Latar Belakang
    • Misi dan Visi
    • Organisasi
    • Piagam Pelanggan
    • Video Korporat
    • Kepakaran Kami
    • Pengakuan
    • Brosur
  • Ahli akademik
    • Sarjana Sains
    • Doktor Falsafah
    • Pelajar Pascasiswazah
    • Alumni
  • Penyelidikan
    • Aktiviti Penyelidikan
      • Bidang Penyelidikan
      • Fokus Penyelidikan
      • Projek Penyelidikan
        • Produk
      • Kerjasama
      • Penerbitan
        • Papan skor
    • Kemudahan Penyelidikan
  • Hubungi Kami
    • Direktori Kakitangan
    • Maklum balas
  • Galeri
    • Video
    • Audio
  • Muat turun
    • Arkib
    • Penerbitan
    • Borang
    • Kesedaran OBE
    • Laporan
  • Pautan Pantas
    • Pautan Sokongan
    • Soalan Lazim
    • Peta Laman
    • Fakulti
    • Jabatan Lain
    • Acara

Archives for December 2022

Analisis impedimetrik elektrokimia Faradaik pada permukaan yang dihiasi MoS2/Au-NP untuk pengesanan protein C-reaktif

December 7, 2022 Oleh Editor

Abstract – Background: A label-free Faradaic electrochemical impedimetric was developed for a highly sensitive detection of C-reactive protein using a gold interdigitated microelectrode bio-sensing platform enhanced by a gold nanoparticle-decorated molybdenum disulfide (Au-NPs/MoS2) nanosheet via selected chemical linking processes. C-reactive protein (C-RP), a crystalline protein, generates by the liver and hikes when there is inflammation throughout the patients’ body. The concentrations of C-RP plasma levels tend to increase rapidly when the patient facing major injury which will lead to cardiovascular disease (CVD). Methods: The 5 µm microelectrode and gap size g-IDE with the nanostructured materials was demonstrated to increase the impedimetric detection response in Faradaic-mode electrochemical impedance spectroscopy high performance detection environment. The high surface area-to-volume ratio of the modified Au-NPs/MoS2 nanocomposite increased the probes loading onto the transducer and enhanced the impedimetric detection response of the C-RP target post-binding due to an amplified net change in the charge transfer resistance. The developed immunoassay revealed a linear detection of C-RP biomarker in a logarithmic-scale from as low as 1 fg/mL up to 1 µg/mL, and a limit of detection of 0.01 fg/mL. The sensor shows great potential as an early warning risk for cardiovascular disease at a threshold concentration value of C-RP at 1 µg/mL. Significant findings: The biosensor demonstrates an excellent discrimination against other competing proteins in serum, exhibiting the highest predilection to C-RP spiked human serum target. The sensor’s reproducibility is reported within an acceptable range of relative standard deviation of 1–4% for n = 3.

Corresponding Author: Assoc. Prof. Ir. Dr. Mohd Khairuddin Md Arshad
Corresponding Author’s Email: mohd.khairuddin@unimap.edu.my

Download Abstract: PDF
Link to Publication: https://doi.org/10.1016/j.jtice.2022.104450

Filed Under: Publications Tagged With: Biomarker, Biosensor, Impedance spectroscopy, Interdigitated microelectrode, Molybdenum disulfide

BERITA @ INEE

  • IJNeaM Achieves a JCR Impact Factor of 0.8
  • Taklimat Hala Tuju Penyelidikan oleh Timbalan Naib Canselor Penyelidikan & Inovasi (TNC P&I) dan Pencapaian INEE 2022-2025
  • Sentuhan Kasih INEE 2026M/1447H
  • Program Cahaya Prihatin: Elektrik Untuk Masyarakat 2025
  • Persidangan Antarabangsa ke-2 mengenai Nanoteknologi & Penyelidikan Bahan (ICONMAR 2025)

ACARA & AKTIVITI

  • Lawatan daripada Fakulti Teknologi Lanjutan dan Pelbagai Disiplin (FTMM), Universitas Airlangga
  • Lawatan daripada Syarikat Aromaticroot
  • Panggilan untuk Kertas Kerja: BOND21 2026
  • Lawatan oleh Pelajar SJK (C) Nan Kwang
  • Jelajah INEE Nano – Siri 4
Dasar Privasi | Dasar Keselamatan | Penafian | Peta Laman | Soalan Lazim | Maklum balas | Panduan Pengguna | Muat turun | Siswazah

Institut Kejuruteraan Nano Elektronik, Universiti Malaysia Perlis
Lot 106, 108 & 110, Blok A, Taman Pertiwi Indah,
Jalan Kangar-Alor Setar, Seriab 01000 Kangar, Perlis, Malaysia
Tel: +604-979 8581 Faks: +604-979 8578 Emel: webmaster.inee@unimap.edu.my

Hak Cipta © INEE UniMAP

  • Facebook
  • Instagram
  • Twitter
  • YouTube

Untuk paparan terbaik, sila gunakan versi terkini Internet Explorer, Mozilla Firefox dan Google Chrome dengan resolusi 1280 x 768 dan ke atas.

Rakan Kongsi BioNexus (BNP)

QS 5 Bintang

myGov

Logo UniMAP

Designed by Mohd Isa from Portal Kerjaya & Sumber Rujukan Malaysia

  • English