Institute of Nano Electronic Engineering

Universiti Malaysia Perlis

  • Facebook
  • Instagram
  • Twitter
  • YouTube
  • About Us
    • Background
    • Mission and Vision
    • Organization
    • Client’s Charter
    • Corporate Video
    • Our Expertise
    • Acknowledgement
    • Brochures
  • Academics
    • Master of Science
    • Doctor of Philosophy
    • Postgraduate Students
    • Alumni
  • Research
    • Research Activities
      • Research Areas
      • Research Focus
      • Research Projects
        • Products
      • Collaborations
      • Publications
        • Scoreboard
    • Research Facilities
  • Contact Us
    • Staff Directory
    • Feedback
  • Gallery
    • Video
    • Audio
  • Download
    • Archive
    • Publications
    • Forms
    • OBE Awareness
    • Reports
  • Quick Links
    • Support Links
    • FAQ
    • Sitemap
    • Faculty
    • Other Departments
    • Events

Effect of Manganese Content on the Fabrication of Porous Anodic Alumina

January 21, 2014 By Editor

The influence of manganese content on the formation of well-ordered porous anodic alumina was studied. Porous anodic alumina has been produced on aluminium substrate of different manganese content by single-step anodizing at 50V in 0.3M oxalic acid at 15◦C for 60 minutes. The well-ordered pore and cell structure was revealed by subjecting the porous anodic alumina to oxide dissolution treatment in a mixture of chromic acid and phosphoric acid. It was found that the manganese content above 1wt% impaired the regularity of the cell and pore structure significantly, which can be attributed to the presence of secondary phases in the starting material with manganese content above 1wt%. The pore diameter and interpore distance decreased with the addition of manganese into the substrates. The time variation of current density and the thickness of porous anodic alumina also decreased as a function of the manganese content in the substrates.

Corresponding Author: C.H. Voon
Corresponding Author’s Email: chvoon@unimap.edu.my

Full text: PDF

Filed Under: Publications Tagged With: chromic acid, phosphoric acid, porous anodic alumina

Synthesis of single-walled carbon nanotubes by chemical vapor deposition using sodium chloride support

September 4, 2013 By Editor

Abstract – Bundled single-walled carbon nanotubes (SWCNTs) together with multi-walled carbon nanotubes (MWCNTs) were directly grown on a water-soluble support catalyst that was prepared via sublimation of ferrocene on sodium chloride. The synthesis of nanotubes was carried out at a growth temperature of 700 °C in a combined methane and nitrogen environment of 1:1 volumetric ratio at a total flowrate of 80 ml/min for 1 h in a vertical reactor. Characterization techniques such as scanning electron microscope, transmission electron microscope, thermogravimetric analysis, and Raman spectroscopy were employed to study the carbon deposits. Transmission electron microscope shows the presence of SWCNTs with an average diameter of ca. 1.18 nm on the catalyst. The radial breathing mode (RBM) of Raman for shifts below 350 -1cm further confirmed the presence of SWCNTs and the diameters were calculated to be 0.93, 1.36, 1.5 and 1.85nm.

Keywords – Single-walled carbon nanotubes, Multi-walled carbon nanotubes, Electron microscopy, Raman spectroscopy

Corresponding Author: Liu Wei Wen
Corresponding Author’s Email: wwliu@unimap.edu.my

Full text: PDF

Filed Under: Publications Tagged With: Electron microscopy, Multi-walled carbon nanotubes, Raman spectroscopy, Single-walled carbon nanotubes

Aptamer-based biosensor for sensitive PDGF detection using diamond transistor

May 2, 2013 By Editor

Abstract – The detection of platelet-derived growth factor (PDGF) via a solution-gate field-effect transistor (SGFET) has been demonstrated for the first time using aptamers immobilized on a diamond surface. Upon introduction of PDGF to the immobilized aptamer, a shift of 31.7mV in the negative direction is observed at a source-drain current of −50µA. A shift of 32.3mV in the positive direction is detected after regeneration by SDS solution, indicating that the static measurement returns to its original value. These SGFETs operate stably within the large potential window of diamond (>3.0 V), and hence the surface channel does not need passivating with a thick insulating layer. Thereof, the immobilized aptamer channels have been exposed directly to the electrolyte solution without a gate insulator. Immobilization is achieved via aptamers covalently bonding to amine sites, thereby increasing the sensitivity of the biosensors. Diamond SGFETs have potential for the detection of PDGF and show durability against biological degradation after repeated usage and regeneration.

Keywords – Aptamer, Diamond transistor, Platelet-derived growth factor, Biosensor

Corresponding Author: Ruslinda Abdul Rahim
Corresponding Author’s Email: ruslinda@unimap.edu.my

Full text: PDF

Filed Under: Publications Tagged With: Aptamer, Biosensor, Diamond transistor, Platelet-derived growth factor

Effects of diamond-FET-based RNA aptamer sensing for detection of real sample of HIV-1 Tat protein

April 29, 2013 By Editor

Abstract – Diamond is a promising material for merging solid-state and biological systems owing to its chemical stability, low background current, wide potential window and biocompatibility. The effects of surface charge density on human immunodeficiency virus type 1 Trans-activator transcription (HIV-1 Tat) protein binding have been investigated on a diamond field-effect transistor (FET) using ribonucleic acid (RNA) aptamers as a sensing element on a solid surface. A change in the gate potential of 91.6 mV was observed, whereby a shift in the negative direction was observed at a source-drain current of -8µA in the presence of HIV-1 Tat protein bound to the RNA aptamers. Moreover, the reversible change in gate potential caused by the binding and regeneration cycles was very stable throughout cyclical detections. The stable immobilization is achieved via RNA aptamers covalently bonded to the carboxyl-terminated terephtalic acids on amine sites, thereby increasing the sensitivity of the HIV-1 Tat protein sensor. The reliable use of a real sample of HIV-1 Tat protein by an aptamer-FET was demonstrated for the first time, which showed the potential of diamond biointerfaces in clinical biosensor applications.

Keywords – RNA aptamer, Diamond FET, HIV-1 Tat protein, Biosensor

Corresponding Author: Ruslinda Abdul Rahim
Corresponding Author’s Email: ruslinda@unimap.edu.my

Full text: PDF

Filed Under: Publications Tagged With: Biosensor, Diamond FET, HIV-1 Tat protein, RNA aptamer

Nanotechnology development status in Malaysia: Industrialization Strategy and Practices

April 25, 2013 By Editor

Abstract – Malaysia has started it own micro-technology and nanotechnology development since the early millennium year of 2000 and arise until this day. Some key plans have proven effective and others fairly not. Status about strategies and practices planned in Malaysia with some relevant finding through experiences in industries collaboration observations and UniMAP involvement in nanotechnology are presented in this paper. Some suggestion and ideas are also presented.

Keywords – Nanotechnology, R&D, Industry, Strategy, Practice, Malaysia.

Corresponding Author: Prof. Dr. Uda Hashim
Corresponding Author’s Email: uda@unimap.edu.my

Full text: PDF

Filed Under: Publications Tagged With: Industry, malaysia, nanotechnology, Practice, R&D, Strategy

  • « Previous Page
  • 1
  • …
  • 9
  • 10
  • 11
  • 12
  • 13
  • Next Page »

NEWS @ INEE

  • IJNeaM Achieves a JCR Impact Factor of 0.8
  • Research Direction Briefing by the Deputy Vice-Chancellor of Research & Innovation (TNC P&I) and INEE Achievements 2022-2025
  • Sentuhan Kasih INEE 2026M/1447H
  • Cahaya Prihatin Program: Electricity for the Community 2025
  • The 2nd International Conference on Nanotechnology & Materials Research (ICONMAR 2025)

EVENTS & ACTIVITIES

  • Visit from the Faculty of Advanced and Multidisciplinary Technology (FTMM), Universitas Airlangga
  • Visit from Aromaticroot Company
  • Call for Papers: BOND21 2026
  • Visit by SJK (C) Nan Kwang Students
  • INEE Nano Roadshow – Series 4
Privacy Policy | Security Policy | Disclaimer | Sitemap | FAQ | Feedback | User Guide | Download | Postgraduate

Institute of Nano Electronic Engineering, Universiti Malaysia Perlis
Lot 106, 108 & 110, Blok A, Taman Pertiwi Indah,
Jalan Kangar-Alor Setar, Seriab 01000 Kangar, Perlis, Malaysia
Tel: +604-979 8581 Fax: +604-979 8578 Email: webmaster.inee@unimap.edu.my

Copyright © INEE UniMAP

  • Facebook
  • Instagram
  • Twitter
  • YouTube

For best view, please use latest version of Internet Explorer, Mozilla Firefox and Google Chrome with resolution 1280 x 768 and above.

BioNexus Partners (BNP)

QS 5 Stars

myGov

Logo UniMAP

Designed by Mohd Isa from Portal Kerjaya & Sumber Rujukan Malaysia

  • English