Institut Kejuruteraan Nano Elektronik

Universiti Malaysia Perlis

  • Facebook
  • Instagram
  • Twitter
  • YouTube
  • Tentang Kami
    • Latar Belakang
    • Misi dan Visi
    • Organisasi
    • Piagam Pelanggan
    • Video Korporat
    • Kepakaran Kami
    • Pengakuan
    • Brosur
  • Ahli akademik
    • Sarjana Sains
    • Doktor Falsafah
    • Pelajar Pascasiswazah
    • Alumni
  • Penyelidikan
    • Aktiviti Penyelidikan
      • Bidang Penyelidikan
      • Fokus Penyelidikan
      • Projek Penyelidikan
        • Produk
      • Kerjasama
      • Penerbitan
        • Papan skor
    • Kemudahan Penyelidikan
  • Hubungi Kami
    • Direktori Kakitangan
    • Maklum balas
  • Galeri
    • Video
    • Audio
  • Muat turun
    • Arkib
    • Penerbitan
    • Borang
    • Kesedaran OBE
    • Laporan
  • Pautan Pantas
    • Pautan Sokongan
    • Soalan Lazim
    • Peta Laman
    • Fakulti
    • Jabatan Lain
    • Acara

Substrate-gate coupling in ZnO-FET biosensor for cardiac troponin I detection

17 Mac 2017 Oleh Editor

Abstract – Currently, field-effect transistor (FET)-based biosensors have been implemented in several portable sensors with the ultimate application in point-of-care testing (POCT). In this paper, we have designed substrate-gate coupling in FET-based biosensor for the detection of cardiac troponin I (cTnI) biomarker. In the device structure, zinc oxide nanoparticles (ZnO-NPs) thin film were deposited through sol-gel and spin coating techniques on the channel. The p-type silicon was used as a substrate, while ZnO is an n-type nanomaterial, thus creates p-n-p junction between source, channel, and drain. The deposited thin films exhibited hexagonal wurtzite phase of ZnO, suitable for biomolecular interaction as revealed in X-ray diffraction (XRD) analysis. The surface of the thin film was then functionalized with 3-aminopropyltriethoxysilane (APTES), followed by glutaraldehyde (GA) as a bi-functional linker to immobilize the cTnI monoclonal antibody (MAb-cTnI) as bio-receptor for capturing cTnI biomarker and proven by the Fourier transform-infrared (FT-IR) spectra. Lastly, we demonstrated a new strategy, the integration of FET-based biosensors with substrate-gate showed differences between before (immobilization) and after cTnI target biomarker interaction by significant changes in drain current (ID) and change of threshold voltage (VT), which improved the sensitive detection, with the limit of detection down to 3.24 pg/ml.

Keywords – Biosensor, Cardiac troponin I, Electrical-based, Field-effect transistor, Substrate-gate coupling, Zinc oxide nanoparticles

Penulis Berkaitan: Uda Hashim
Emel Pengarang Berkaitan: uda@unimap.edu.my

Teks penuh: PDF

Filed Under: Publications Tagged With: Biosensor, Cardiac troponin I, Electrical-based, Field-effect transistor, Substrate-gate coupling, Zinc oxide nanoparticles

BERITA @ INEE

  • IJNeaM Achieves a JCR Impact Factor of 0.8
  • Taklimat Hala Tuju Penyelidikan oleh Timbalan Naib Canselor Penyelidikan & Inovasi (TNC P&I) dan Pencapaian INEE 2022-2025
  • Sentuhan Kasih INEE 2026M/1447H
  • Program Cahaya Prihatin: Elektrik Untuk Masyarakat 2025
  • Persidangan Antarabangsa ke-2 mengenai Nanoteknologi & Penyelidikan Bahan (ICONMAR 2025)

ACARA & AKTIVITI

  • Lawatan daripada Fakulti Teknologi Lanjutan dan Pelbagai Disiplin (FTMM), Universitas Airlangga
  • Lawatan daripada Syarikat Aromaticroot
  • Panggilan untuk Kertas Kerja: BOND21 2026
  • Lawatan oleh Pelajar SJK (C) Nan Kwang
  • Jelajah INEE Nano – Siri 4
Dasar Privasi | Dasar Keselamatan | Penafian | Peta Laman | Soalan Lazim | Maklum balas | Panduan Pengguna | Muat turun | Siswazah

Institut Kejuruteraan Nano Elektronik, Universiti Malaysia Perlis
Lot 106, 108 & 110, Blok A, Taman Pertiwi Indah,
Jalan Kangar-Alor Setar, Seriab 01000 Kangar, Perlis, Malaysia
Tel: +604-979 8581 Faks: +604-979 8578 Emel: webmaster.inee@unimap.edu.my

Hak Cipta © INEE UniMAP

  • Facebook
  • Instagram
  • Twitter
  • YouTube

Untuk paparan terbaik, sila gunakan versi terkini Internet Explorer, Mozilla Firefox dan Google Chrome dengan resolusi 1280 x 768 dan ke atas.

Rakan Kongsi BioNexus (BNP)

QS 5 Bintang

myGov

Logo UniMAP

Designed by Mohd Isa from Portal Kerjaya & Sumber Rujukan Malaysia

  • English